成人a免费I日韩午夜在线播放I麻豆传媒观看I四虎av在线播放I成人av软件I中文字幕国产I性丰满白嫩白嫩的hd124I91国内精品久久久I午夜在线免费观看视频I精品二三区I国产精品视频久久I精品不卡一区I欧美成人女星I99riav视频I欧美性成人Iav资源一区I久久人人澡I精品一区不卡I色偷偷噜噜噜亚洲男人的天堂I亚洲熟妇无码avIwww.日日干I一级片视频网站I成人片在线播放I亚洲v精品I自拍视频一区I久久亚洲中文字幕无码I成人毛片av

產品展示
PRODUCT DISPLAY

打印當前頁

免費咨詢:021-67610176

發郵件給我們:market@hsiyen.cn

分享到:
產品展示您現在的位置: 首頁 > 產品展示 > > 美國戴安Dionex > 美國戴安 P/N: 083225Dionex IonPac AS19-4µm Column 陰離子

Dionex IonPac AS19-4µm Column 陰離子

簡要描述:

戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。

型號 美國戴安 P/N: 083225
廠商性質 代理商
更新日期 2018-04-23

Dionex IonPac AS19-4?m 

Hydroxide-Selective Anion-Exchange Column

Higher Resolution of Trace Oxyhalides and Inorganic Anions in Complex Matrices using Smaller Particle Columns

Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using the Dionex IonPac AS19-4?m hydroxide-selective anion-exchange column. Its high resolution, high capacity and selectivity allow the determination of bromate in drinking water at the low-μg/L level. Compared to the previous Dionex IonPac AS19 column, the new anion-exchange column uses smaller resin particles for more efficient separations resulting in more accurate peak integration and more reliable results. It has similar selectivity and increased peak efficiencies compared to the Dionex IonPac AS19 column, ensuring that applications run on the Dionex IonPac AS19 can be easily transferred to the Dionex IonPac AS19-4?m column. The Dionex IonPac AS19-4?m columns meets the performance requirements of US EPA Methods 300.0 and 300.1.

The Dionex IonPac AS19-4?m column is available in three formats: 4 × 250 mm, 2 × 250 mm and 0.4 × 250 mm.The Dionex IonPac AS19-4?m Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate.The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

  • Recommended hydroxide-selective column for trace bromate in drinking water matrices
  • High capacity: 240 μeq per column (4 × 250 mm)
  • Meets or exceeds performance requirements of US EPA Methods 300.0 and 300.1
  • Column selectivity is optimized for 30 °C operating temperature
  • Compatible with organic solvents
  • High-pressure Thermo Scientific Dionex ICS-5000+ or Dionex ICS-4000 HPIC system is required to run at standard flow rates.

The Dionex IonPac AS19-4?m column is designed for the analysis of oxyhalides and common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices. The Dionex IonPac AS19-4?m column allows analysis of most drinking water without the use of sample pretreatment or preconcentration. This column is ideally used with an RFIC system for automatic eluent generation.

The key application for the Dionex IonPac AS19-4?m column is the determination of trace bromate in drinking water matrices using a potassium hydroxide gradient with suppressed conductivity detection. The selectivity of the Dionex IonPac AS19-4?m column ensures that bromate can be quantified at low μg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate.

The smaller resin particles used in the Dionex IonPac AS19-4?m column produce a backpressure over 3000 psi at the standard flow rates. A high-pressure IC system, such as the Dionex ICS-5000+ HPIC or the Dionex ICS-4000 Capillary HPIC system is required.

Note: Use the Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor with the Dionex IonPac AS19-4?m column for eluent suppression.

Dionex IonPac AS19-4?m Anion-Exchange Column Specifications
DimensionsDionex IonPac AS19-4?m Analytical Column:
2 × 250 mm and 4 × 250 mm
Dionex IonPac AG19-4?m Guard Column:
2 × 50 mm and 4 × 50 mm

Dionex IonPac AS19-4?m Capillary Column:
0.4 × 250 mm
Dionex IonPac AG19-4?m Capillary Guard Column:
0.4 × 50 mm
Maximum operating pressure5000 psi (standard and microbore)
5000 psi (capillary)
Ion-exchange groupFunctional Group: Alkanol quaternary ammonium ion
Functional group characteristicsUltralow hydrophobicity
Capacity2.4 ?eq (0.4 × 250 mm capillary column)
0.06 ?eq* (0.4 × 50 mm capillary guard column)
60 ?eq (2 × 250 mm analytical column)
1.5 ?eq* (2 × 50 mm guard column)
240 ?eq (4 × 250 mm analytical column)
6 ?eq* (4 × 50 mm guard column)
*Guards are packed with a low-capacity microporous resin.
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Substrate characteristicsBead Diameter and Pore Size: 4 ?m (0.4 x 250, 2 × 250 and 4 × 250 mm);
super macroporous resin (2000 ?)
11 ?m (0.4 x 50, 2 × 50 and 4 × 50 mm);
microporous resin (<1 ?)
Cross-Linking (%DVB): 55%
phase compatibilitypH 0–14; 0–100% HPLC solvents



Analytical Columns
Dionex IonPac AS19-4?m Analytical Column (4 × 250 mm)083217
Dionex IonPac AS19-4?m Analytical Column (2 × 250 mm)083223
Dionex IonPac AS19-4?m Capillary Column (0.4 × 250 mm)083230
Guard Columns
Dionex IonPac AG19-4?m Guard Column (4 × 50 mm)083221
Dionex IonPac AG19-4?m Guard Column (2 × 50 mm)083225
Dionex IonPac AG19-4?m Capillary Guard Column (0.4 × 50 mm)083233